This reference manual provides detailed information regarding the 2450 source measure unit smu instrument. During the warranty period, we will, at our option, either repair or replace any product that proves to be defective. Corporate headquarters 28775 aurora road cleveland, ohio 449 4402480400 fax. A june 2014 p245090501a 245090501 a tektronix company a greater measure of confidence model 2450.
Easy iv characterization of diodes using the model 2450. Keithley 2450 sourcemeter this goto instrument of choice for todays laboratories is the fourth generation member of keithleys sourcemeter family of source measure unit smu models. See the model 2450 interactive sourcemeter instrument reference manual document number 245090101 for more information. H february 2009 model 2001 multimeter operators manual. Level measurements handbook, which can be downloaded from. Application note leakage current and insulation resistance. Measuring insulation resistance this application sets the model 2450 to source 20 v and reset the instrument, which also clears the buffer. This is most noticeable where the spec ratio is less than 1. Instruction manual model 225 current source publication date. Gpib cable to connect both and gpib usb dongle in my case ni usbgpibhs raspberry pi i used 1 model b, rev. Model 2460 highcurrent sourcemeter instrument reference manual includes advanced operation topics, maintenance information, troubleshooting procedures, and indepth descriptions of programming commands. Model 6487 picoammetervoltage source reference manual. Keithley 2450 reference manual reference manual 878 pages keithley 6517a getting started manual getting started manual.
Database contains 3 keithley sourcemeter 2420 manuals available for free online viewing or downloading in pdf. L november 2018 upgrade considerations for the model 2450 attention. Problem programming sense function 2450 tektronix and. If you need to know details of calibration procedure, you can reference to keithley model 2400 service manual. The keithley model 191 is a 5l2 digit, 200,000count, manualranging bench digital multi meter with dc volts and ohms ranges standard. Page 95 all other trademarks and trade names are the property of their respective companies. This users manual provides basic instrument information and applications for the 2450 source measure unit instrument. Model 2450 interactive sourcemeter instrument specifications. A g r e a t e r m e a s u r e o f c o n f i d e n c e w w w. Specifications are subject to change without notice. The 2450 is easytouse, regardless of the users level of smu experience, and has capabilities ranging from basic purpose to the most advanced measurement.
Users manual for model 2701 ethernetbased dmm data acquisition system on. Users manual for model 2701 ethernetbased dmm data acquisition system. This fourth generation, all in one truly brings ohms law current, voltage and resistance testing right to fingertips. This manual provides detailed applications to help you achieve success with your keithley instruments model 2450. For related documentation, software tools, and drivers, see the model 2450 interactive sourcemeter instrument product information cdrom. Keithleys model 2450 sourcemeter smu instrument, is ideal. Source meters collect information with high accuracy, ideal for currentvoltage iv characterization, semiconductor testing, and testing devices with both positive and. The model dmm7510 712 digit graphical sampling multimeter reference manual is a complete reference that contains information on general operation, functions and features, using scpi and tsp commands over a remote interface, maintenance, using the status model and more. To use other programming environments, you may need to make changes to the example tsp code. K september 2011 99 washington street melrose, ma 02176. Any unauthorized reproduction, photocopy, or use of the information herein, in whole. Model 2634b2636b model 2635b similar when connecting to models 2611b, 2612b, 2614b, 2634b, 2635b, and 2636b smu outputs using cables not rated for voltages above 42v, such as the 2600aalg2, you must disable the high voltage output by using.
Model 2001 multimeter operators manual mhz electronics. Model 2100 6 12digit resolution digital multimeter user. Model 2450 interactive sourcemeter instrument users. Model 2450 sourcemeter instrument reference manual. Database contains 1 keithley sourcemeter 2460 manuals available for free online viewing or downloading in pdf. Model 6485 picoammeter model 6487 picoammetervoltage source users manual 648790001 rev. This instrument can operate as a sensitive, electronic load to discharge a battery. For more detailed information, refer to the keithley instruments model 2450 reference manual. View online or download keithley interactive sourcemeter 2450 user manual. Keithley interactive sourcemeter 2450 pdf user manuals. The 2450 is keithleys nextgeneration sourcemeter source measure. Keithley model 2400 for calibration with gpib address 24. In addition, it can execute test scripts to monitor battery.
Keithley bench psu adjustable voltage 2636a 0 200 v 0. User manuals, guides and specifications for your keithley sourcemeter 2420 measuring instruments. Source meter instruments are a type of electronic test equipment that measures and logs precise voltage and current data. We have 2 keithley interactive sourcemeter 2450 manuals available for free pdf download. Unmatched system integration and programming flexibility when the 2450 is integrated as part of a multichannel iv test system. Keithley instruments products are designed for use with elec trical signals that are rated measurement category i. Hazardous voltages may be present on all output and guard terminals. Model 2450 interactive sourcemeter instrument reference manual. The keithley 2450ec includes a wide range of voltages and currents for sourcing or measuring, nv fa sensitivities, and high impedance sense leads with a typical input resistance of 50 gohms and only 1pa of input bias current, typically acceptable with a wide variety of reference electrodes. Keithley interactive sourcemeter 2450 user manual pdf. Make offer keithley 197 autoranging microvolt dmm instruction manual and quick reference. Model 2450 interactive sourcemeter instrument users manual. Keithley instruction manual model 147 nanovolt null detector.
General operation model 2450 interactive sourcemeter instrument reference manual keithley instruments connector cs16163, supplied with the model 2450, can be used to make the interlock connection to the rear panel. Model 2400 scpi to model 2450 scpi command cross reference. Model 2460 highcurrent sourcemeter instrument reference. The 2420 from keithley, is a 60 w source measure unit smu.
General information model 2450 sourcemeter version 1. The model 2450 is keithleys nextgeneration sourcemeter source measure unit smu instrument that truly brings ohms law current, voltage, and. They offer a smart alternative to separate power supplies and dmms. Model 2100 6 12digit resolution digital multimeter users manual 210090001 rev. By default, the model 2450 is configured to use the scpi from the instrument console, you can copy the data into a command set. The complete set of scpi commands for the model 2450 is in section 6 of the reference manual. Model 2450 sourcemeter instrument reference manual includes advanced operation topics, maintenance information, troubleshooting procedures, and. Series 2280 precision measurement dc power supplies reference manual 077085500 june 2014 p077085500 077085500 a t ektr onix company series 2280 precision measurement dc power supplies reference manual. Keithley 2450ec graphical potentiostat, 200v, 1a, 20w. Triplechannel dc power supply reference manual 077100401 september 2014 p077100401 077100401 a tektronix company model 2231a303. The 2450 is keithleys sourcemeter source measure unit smus source current or voltage and simultaneously measure current, voltage and resistance with high speed and accuracy.
This revision is intended for use with firmware version 1. Keithley instruments products are designed for use with electrical signals that are rated measurement category i. It provides information about the front panel to familiarize you with the instrument. Unlike conventional instruments with dedicated push. The smu features a max current source of 3 a, a max voltage source of 60 v, and a measurement resolution of 10100 currentvoltage.